Air Managers and Exhaust Chimneys

Great Lakes Exhaust chimney serves as a duct that assists in the removal of hot air from ES Server enclosures. This process of directing and removing exhaust air can be accelerated through the use of a chimney fan tray. A soft grommet seal at the top of the chimney ensures a tight fit between the chimney and the ceiling. The chimney is available in two different sizes with varying ranges of adjustability. 
Find out more! 

When enclosures in a row do not align with ceiling tiles and the overhead duct system, the Flexible Duct Chimney Kit is an ideal solution! The kit comes with a 24" x 24" ceiling panel to be installed in the drop ceiling. Black polyester hose attaches to the ceiling panel and an adapter on the top of the enclosure.

Exhaust Chimney  (fully compressed & extended) HIGH FLOW EXHAUST CHIMNEY & FAN TRAY

Exhaust Chimney 
(fully compressed & extended)

Standard Chimney Fan Tray HIGH FLOW EXHAUST CHIMNEY & FAN TRAY

Standard Chimney Fan Tray

Flexible Duct Chimney HIGH FLOW EXHAUST CHIMNEY & FAN TRAY

Flexible Duct Chimney

High Flow Exhaust Chimney & Fan Tray

GL-ECHF-48-1832 - High Flow Chimney for 48"D ES Enclosure with an adjustable range of 18" to 32"
GL-ECHF-48-3246 - High Flow Chimney for 48"D ES Enclosure with an adjustable range of 32" to 46"
GL-ECHFT48 - High Flow Fan Tray for 48"D Enclosure, 2260 CFM

Exhaust Chimney & Fan Tray

GL-EC-42-1832 - Exhaust chimney for 42"D Enclosure with an adjustable range of 18-32"
GL-EC-42-3246 - Exhaust chimney for 42"D Enclosure with an adjustable range of 32-46"
GL-EC-48-1832 - Exhaust chimney for 48"D Enclosure with an adjustable range of 18-32"
GL-EC-48-3246 - Exhaust chimney for 48"D Enclosure with an adjustable range of 32-46"
GL-ECFT42 - Optional fan tray for 42"D Enclosure, 1200 CFM
GL-ECFT48 - Optional fan tray for 48"D Enclosure, 1200 CFM

Flexible Duct Chimney

ECDHF48 - High Flow Flexible Chimney Kit for 48"D Enclosures; kit includes 24" x 24" ceiling panel, high flow enclosure adapter, two 5' sections of double ply black polyester fabric hoses, and four duct collars
GL-ECHFT48 - High Flow Fan Tray for 48"D Enclosure, 2260 CFM
ECD48 - Flexible Chimney Kit for 48"D Enclosures; kit includes 24" x 24" ceiling panel, enclosure adapter, two 5' sections of double ply black polyester fabric hoses, and four duct collars
GL-ECFT48 - Optional fan tray for 48"D enclosure, 1200 CFM

The Great Lakes Adjustable Air Manager mounts to the bottom of an ES Server enclosure, “managing” the flow of conditioned air into the enclosure. An adjustable slide allows the amount of air to be adjusted as necessary, while maintaining raised floor pressure throughout the data center. This process can also be further enhanced through the use of a fan tray. The Air Manager mounts to the bottom one or two RMU. Find out more!

Standard Air Manager HIGH FLOW AIR MANAGER

Standard Air Manager

Standard Air Manager Fan Tray HIGH FLOW AIR MANAGER

Standard Air Manager Fan Tray

Side Airflow Manager HIGH FLOW AIR MANAGER

Side Airflow Manager

High Flow Air Manager

AM-HFES - High Flow Air Manager Assembly, 19" EIA, for 78"H and 84" ES Enclosures, 2 RMU
AM-HFFTES24 - High Flow Air Manager Fan Tray, for 24"W Enclosure, 940 CFM
AM-HFFTES30 - High Flow Air Manager Fan Tray, for 30"W Enclosure, 940 CFM

Air Manager & Fan Tray

AM-ES - Standard Air Manager Assembly, 19" EIA, for 78" H and 84" ES Enclosures, 1 RMU
AM-FTES24 - Standard Air Manager Fan Tray for 24" W Enclosure, 1 RMU, 600 CFM
AM-FTES30 - Standard Air Manager Fan Tray for 30" W Enclosure, 1 RMU, 600 CFM

Side Airflow Manager

AM-SES - Air Manager for use when side-to-side airflow equipment is installed

Aisle Containment Doors

Many times cooling challenges cannot be met simply by expanding infrastructure or adding additional CRAC units. The strategy behind containment is to either capture as much conditioned air as possible or isolate and remove as much exhaust as possible.

Cold Aisle Containment

Use aisle containment doors to create a volume of conditioned air. The area in front of enclosures is saturated with cold air and is able to be focused where it is needed the most, in front of the equipment mounted within the enclosure. This strategy eliminates the need of flood cooling throughout the data center and greatly reduces bypass airflow.

Heated exhaust is vented into the hot aisle which is contained by aisle doors. This volume of hot air is returned to the CRAC unit, creating a more efficient cooling circuit; higher exhaust temperatures result in improved cooling from the CRAC unit.

Hot Aisle Containment

Aisle Containment Doors With Quick Release

• Push open from inside the aisle; pulled open from outside of the aisle

• Slide open from inside or outside the aisle

• Available in black or advantage white for 42, 44, and 48 RMU ES Enclosures

• Installed across aisle widths of 48-72"

• Brush grommet along bottom and outer edge to seal openings and prevent air recirculation

Find Out More!

ACDQR91 - Aisle Containment Doors with Quick Release for 91"H ES and EN Enclosures

ACDQR84 - Aisle Containment Doors with Quick Release for 84"H ES and EN Enclosures

ACDQR79 - Aisle Containment Doors with Quick Release for 79"H ES and 78"H EN
Enclosures

Note: Doors are made to order. Please call for lead time.

Sliding Aisle Containment Doors

• Slide open from inside or outside the aisle

• Available in black or advantage white for 42, 44, and 48 RMU ES Enclosures

• Installed across aisle widths of 48-72"

• Brush grommet along bottom and outer edge to seal openings and prevent air recirculation

ACD910ES - Aisle Containment Doors for 91"H ES and EN Enclosures

ACD840ES - Aisle Containment Doors for 84"H ES and EN Enclosures

ACD790ES - Aisle Containment Doors for 79"H ES and 78"H EN Enclosures

Baffle Kits
EN and ES baffle kits

Baffle Kits create proper airflow for switches and side-to-side airflow equipment, as suggested by manufacturers such as Cisco. Cool air is channeled into the equipment along the right side and exhaust air is directed out along the left side of the equipment. Kits are tool-less and easily attach to rails outside of the EIA mounting profile. 

Based on your switch/equipment, choose the appropriate EN enclosure or ES enclosure. Take into consideration your cable management, cooling, and power needs; each enclosure addresses these needs in different ways. Baffle Kit part numbers are specific to EN or ES Enclosures. 

The Baffle Kit Matrix below shows which kits accommodate various Cisco switches. Other brands of side-to-side airflow equipment can also be mounted. To determine the correct enclosure and baffle kit, compare physical equipment dimensions to what is listed. ***PLEASE TURN PHONE SIDEWAYS TO SEE BAFFLE KIT MATRIX.***

               
Recommended
Great Lakes Enclosures
Great Lakes
Baffle Kit
Part No.
CISCO
Equipment
Dimensions
CISCO Recommended
Clearances
EN Series
Enclosures
ES Series
Enclosures
EN Baffle Kits ES Baffle Kits RMU Depth Distance from
equipment to wall
(i.e. enclosure side panel,
or side of baffle kit)
7000
Series
7018140"W x 48"DN/AENSAB25N/A2533.111
7010232/40"W x 48"D30"W x 48"DN/AN/A2133.1N/A
700940"W x 48"DN/AENSAB14AN/A1424.1011
7004340"W x 48"DN/AENSAB7AN/A72411
9500
Series
951332"W x 42/48"D30"W x 42/48"DENSAB14DESSAB14D14286
950932"W x 42/48"D30"W x 42/48"DENSAB14ESSAB141418.402.50
6800
Series
6807-XL32"W x 42/48"D30"W x 42/48"DENSAB10D18ESSAB10D181018.106
6880-X532"W x 42/48"D30"W x 42/48"DENSAB5D23ESSAB5D235236
6500
Series
6513 (-E)32"W x 42/48"D30"W x 42/48"DENSAB19ESSAB191918.106
6509 (-E)32"W x 42/48"D30"W x 42/48"DENSAB14ESSAB141418.106
6506 (-E)32"W x 42/48"D30"W x 42/48"DENSAB11ESSAB111118.106
4500
Series
4510R32"W X42/48"D30"W x 42/48"DENSAB14ESSAB141412.506
450632"W x 42/48"D30"W x 42/48"DENSAB10D18ESSAB10D181012.506
1Four post mounting is required with a rail placement of 24"
2The 7010 has front to rear airflow; no left or right side clearance is required; when installed in a cabinet, 5" rear clearance is required
3The 7004 requires 11" clearance on the right (intake) side only; exhaust exits from the rear, no rear clearance is require
NOTE: It is important to read and understand CISCO installation guides that are associated with each switch

Baffle Kits for EN Enclosures

PART NO. AND DESCRIPTION

Tech Spec

CFD Report

ENSAB25 - Baffle Kit for use with 28.5"D to 32"D, 14 RMU
Cisco and other side-to-side airflow equipment; for proper airflow, this size switch and baffle should only be used in 40"W enclosures

ENSAB19 - Baffle Kit for use with 15.8"D to 18.5"D, 19 RMU Cisco and other side-to-side airflow equipment

ENSAB14 - Baffle Kit for use with 15.8"D to 18.4"D, 14 RMU Cisco and other side-to-side airflow equipment

ENSAB14A - Baffle Kit for use with 21.9"D to 24.1"D, 14 RMU Cisco and other side-to-side airflow equipment; for proper airflow, this size switch and baffle should only be used in 40"W enclosures

ENSAB14D - Baffle Kit for use with 25.7"D to 32"D, 14 RMU Cisco and other side-to-side airflow equipment

ENSAB11 - Baffle Kit for use with 15.8"D to 18.1"D, 11 RMU Cisco and other side-to-side airflow equipment

ENSAB7A - Baffle Kit for use with 21.8"D to 24"D, 7 RMU Cisco and other side-to-side airflow equipment; for use with 40"W Enclosures

Baffle Kits for 30"W ES Enclosures

PART NO. AND DESCRIPTION

Tech Spec

CFD Report

ESSAB19 - Baffle Kit for use with 15.8"D to 18.5"D, 19 RMU Cisco and other side-to-side airflow equipment

ESSAB14 - Baffle Kit for use with 15.8"D to 18.4"D, 14 RMU Cisco and other side-to-side airflow equipment

ESSAB14D - Baffle Kit for use with 25.7"D to 32"D, 14 RMU
Cisco and other side-to-side airflow equipment

ESSAB11 - Baffle Kit for use with 15.8"D to 18.1"D, 11 RMU Cisco and other side-to-side airflow equipment

NOTE: Although equipment may physically fit into a Great Lakes enclosure, with or without brackets, customers must also review and comply with the equipment manufacturer's installation and other requirements. For example, the E and ES Series Enclosures, when in an open frame configuration, can physically support the installation of a Cisco 7018 Series switch; however, the E and ES Series Enclosure frame designs do not provide the airflow space clearance required by Cisco.

Great Lakes' EN (Enhanced Networking) Series of enclosures is designed to support the installation of Cisco switches and other side-to-side airflow equipment. The EN Series has the airflow space clearances that are currently required and has accessories (including baffle kits) that are designed to support proper operational conditions. For more information, please contact your Great Lakes representative or call 1-866-TRY-GLCC.

When any equipment or accessory is installed in a Great Lakes product, the installation procedures, recommendations and product warranty requirements of the equipment manufacturer must be followed. Great Lakes will not be responsible for any losses or claims arising from a customer's installation of electrical, electronic or other third party products in any Great Lakes enclosure, unless caused solely by a written configuration prepared by Great Lakes for that customer or by a configuration provided by Great Lakes' website, any configuration relies on complete and accurate information from the customer.

Brush Grommet Kits
Brush Grommet Rail Kits for ES Enclosures
Brush Grommet Rail Kits for ES Enclosures

Servers shown for demonstration only.

The Brush Grommet Rail Kit mounts to the outside (does not interfere with the EIA pattern) of Great Lakes mounting rails to prevent hot air (from the rear of servers) from recirculating to the front of servers. The kit is an easy upgrade to existing Great Lakes enclosures, as it installs with tool-less hardware.

Brush Grommet Rail Kits for ES Enclosures

BGRK-79-24 - Brush Grommet Rail Kit for 24"W x 79" ES Enclosures
BGRK-79-30 - Brush Grommet Rail Kit for 30"W x 79" ES Enclosures
BGRK-84-24 - Brush Grommet Rail Kit for 24"W x 84"H ES Enclosures
BGRK-84-30 - Brush Grommet Rail Kit for 30"W x 84"H ES Enclosures
BGRK-91-24 - Brush Grommet Rail Kit for 24"W x 91"H ES Enclosures
BGRK-91-30 - Brush Grommet Rail Kit for 30"W x 91"H ES Enclosures

Brush Grommet Rail Kits for EN Enclosures

BGRK-32EN - Brush Grommet Rail Kit for 32"W x 78" and 84"H EN Enclosures
BGRK-40EN - Brush Grommet Rail Kit for 40"W x 78" and 84"H EN Enclosures
BGRK91-32EN - Brush Grommet Rail Kit for 32"W x 91"H EN Enclosures
BGRK91-40EN - Brush Grommet Rail Kit for 40"W x 91"H EN Enclosures

Brush Grommet for Cable Pass Through, ES Enclosures

Rear vertical cable pass through on ES enclosure is pictured

Brush Grommet for Cable Pass Through, ES Enclosures

BGT - Brush Grommet to cover top cable pass throughs on ES Enclosures, includes edge grommet
BGS-79 - Brush Grommet to cover rear vertical cable pass throughs, includes edge grommet; for 79"H ES Enclosures
BGS-79-48 - Brush Grommet to cover rear vertical cable pass throughs, includes edge grommet; for 79"H x 48"D ES Enclosures
BGS-84 - Brush Grommet to cover rear vertical cable pass throughs, includes edge grommet; for 84"H x 42"D ES Enclosures
BGS-84-48 - Brush Grommet to cover rear vertical cable pass throughs, includes edge grommet; for 84"H x 48"D ES Enclosures
BGS-91 - Brush Grommet to cover rear vertical cable pass throughs, includes edge grommet; for 91"H x 42"D ES Enclosures
BGS-91-48 - Brush Grommet to cover rear vertical cable pass throughs, includes edge grommet; for 91"H x 48"D ES Enclosures
GL-EG - Edge grommet for use around metal edge after removal of knockouts; 1/16” edge
thickness, 5/16” edge length, available by the foot

Brush Grommet for Cable Pass Through, EN Enclosures

BGT-32EN42 - Brush Grommet to cover top cable pass throughs on 32"W x 42"D EN Enclosures, includes edge grommet
BGT-32EN48 - Brush Grommet to cover top cable pass throughs on 32"W x 48"D EN Enclosures, includes edge grommet
BGT-40EN42 - Brush Grommet to cover top cable pass throughs on 40"W x 42"D EN Enclosures
BGT-40EN48 - Brush Grommet to cover top cable pass throughs on 40"W x 48"D EN Enclosures
GL-EG - Edge grommet for use around metal edge after removal of knockouts; 1/16” edge
thickness, 5/16” edge length, available by the foot

Fans
Fans for 19″ Mounting

7217LE3

Fans for 19″ Mounting

FTBKT90

Fans for 19″ Mounting

7217FT

Fans for 19″ Mounting

7217FT-3

Fans for 19″ Mounting

7217FT-6

Fans for 19″ Mounting

7217FT-9

Fans

7217FT - Fan assembly with fan guards and three 75 CFM fans, 2 RMU
FTBKT90 - Fan bracket to mount the 7217FT at 90 degree angle
7217FT-3 - Fan tray (adjustable front to back) with fan guards and three 75 CFM fans, 2 RMU
7217FT-6 - Fan tray (adjustable front to back) with fan guards and six 75 CFM fans, 2 RMU
7217FT-9 - Fan tray (adjustable front to back) with fan guards and nine 75 CFM fans, 2 RMU
7217LE3 - Fan Kit with fan guards and three 75 CFM fans, for use with 29″W contour mesh door
7217LE2 - Fan Kit with fan guards and two 75 CFM fans, for use with 24″W contour mesh door

Use a Variable Speed or Thermostat Controller with your fans; Find out more! 

220V and direct current fans are also available. Please call 1-866-TRY-GLCC for information.

Fan Controllers
FTC101 Fan Controller and Cords

FTC101

FTC103 Fan Controller and Cords

FTC103

Fan Controllers

FTC101 - Fan Thermostat Controller, Thermostat controlled 15 amp duplex outlets, UL listed, CSA certified thermostat, 50° to 90°F / 10° to 30°C temperature range, 6 ft. cord.
FTC103 - Variable Speed Fan Controller to throttle fans from 60 - 100% speed; Incudes temperature probe with 10' cord and 3' outlet cord (C13 to C14); 95-250V, 2.0 amp load; Find out more!

Filler Panels

Plastic Filler Panels by HotLok®

1 RMU Panel

1 RMU Panel

2 RMU Panel

2 RMU Panel

2 RMU Panel with Temperature Strip

2 RMU Panel with Temperature Strip

GLHL10031CP - Package of ten, 1 RMU snap-in panels, 19" mounting for use with M6 and #12-24 rails
GLHL10035CP - Package of ten, 1 RMU snap-in panels with temperature strip, 19" mounting for use with M6 and #12-24 rails
GLHL10033CP - Package of five, 2 RMU snap-in panels, 19" mounting for use with M6 and #12-24 rails
GLHL10038CP - Package of five, 2 RMU snap-in panels with temperature strip, 19" mounting for use with M6 and #12-24 rails
GLHL10009CP - Pack of ten temperature strips

1 RMU Standard Filler Panel1 RMU Standard Filler Panel1 RMU Standard Filler Panel1 RMU Standard Fill

Standard Filler Panels

1.75-FP19 - 1.75"H filler panel for 19" mounting, 1 RMU
3.50-FP19 - 3.50"H filler panel for 19" mounting, 2 RMU
5.25-FP19 - 5.25"H filler panel for 19" mounting, 3 RMU
7.00-FP19 - 7.00"H filler panel for 19" mounting, 4 RMU
8.75-FP19 - 8.75"H filler panel for 19" mounting, 5 RMU
14.00-FP19 - 14.00"H filler panel for 19" mounting, 8 RMU

2 RMU Tool-less Filler Panel

Tool-less Filler Panels

1.75-FPTL19 - 1.75"H tool-less filler panel for 19" mounting on M6 rails, 1 RMU
3.50-FPTL19 - 3.50"H tool-less filler panel for 19" mounting on M6 rails, 2 RMU
5.25-FPTL19 - 5.25"H tool-less filler panel for 19" mounting on M6 rails, 3 RMU
7.00-FPTL19 - 7.00"H tool-less filler panel for 19" mounting on M6 rails, 4 RMU
8.75-FPTL19 - 8.75"H tool-less filler panel for 19" mounting on M6 rails, 5 RMU
14.00-FPTL19 - 14.00"H tool-less filler panel for 19" mounting on M6 rails, 8 RMU

1 RMU Filler Panel with Brush Grommet

Filler Panels with Brush Grommet

1.75FP19BG - 1 RMU Filler Panel with Brush Grommet to allow cable pass through
3.50FP19BG - 2 RMU Filler Panel with Brush Grommet to allow cable pass through

FoamBlock™ Air Barrier
FoamBlock™ Air Barrier

In-between equipment

FoamBlock™ Air Barrier

Under the front of enclosures

FoamBlock™ Air Barrier

To fill knockouts in workstations

Use Great Lakes’ flexible FoamBlock™ to seal gaps in the most unique places! The smallest opening within the enclosure (or even a hole in the data center floor) can decrease cooling efficiency and create hot air recirculation. Flexible 24" x 24" FoamBlock™ sheets can be separated and manipulated to fit into these small problem areas. For technical specifications, please download the product spotlight.
Find Out More!

FoamBlock™ Air Barrier

FoamBlock™ - 6 sheets of 24" x 24" high density foam, perforated 1" x 1"

KoldLok® Raised Floor Grommets
Wave Grommet KoldLok Raised Floor Grommets

Wave Grommet

Wave Grommet with Cover KoldLok Raised Floor Grommets

Wave Grommet with Cover

Split Integral Grommet KoldLok Raised Floor Grommets

Split Integral Grommet

Split Mini Grommet KoldLok Raised Floor Grommets

Split Mini Grommet

Split Surface Grommet KoldLok Raised Floor Grommets

Split Surface Grommet

Extended Raised Floor Grommet KoldLok Raised Floor Grommets

Extended Raised Floor Grommet

KoldLok® Raised Floor Grommets

Integral Raised Floor Grommets are designed to seal openings
in new raised floor cutouts prior to the
 installation of cabling.

GLKL20100CP - Wave Raised Floor Grommet to seal 9.25" x 6.75" openings; case pack of 10
GLKL20101CP - Cover for Wave Raised Floor Grommet; case pack of 10
GLKL3030CP - Split Integral Raised Floor Grommet to seal 9.25" x 6.75" openings; case pack of 10
GLKL1010CP - Integral Raised Floor Grommet to seal 9.25" x 6.75" openings; case pack of 10
GLKL10077CP - Split Mini Raised Floor Grommet to seal 4" x 6" openings; case pack of 10
GLKL40001CP - Round 4" Raised Floor Grommet for new and existing cutouts; case pack of 10
GLKL40003CP - Round 6" Raised Floor Grommet for new and existing cutouts; case pack of 10
GLKL10012CP - Extended Raised Floor Grommet for sealing new and existing perimeter openings, 3 in.; case pack of 10
GLKL10013CP - Extended Raised Floor Grommet for sealing new and existing perimeter openings, 6 in.; case pack of 10

KoldLok Surface Mount Grommets

KoldLok® Surface Mount Grommets

Surface Mount Floor Grommets are designed to seal openings in
existing raised floor tile cutouts
 without capturing cables.

GLKL2020CP - Split Surface Mount Raised Floor Grommet to seal
openings 10" x 7.25" or less; case pack of 10
GLKL2030CP - Surface Mount Raised Floor Grommet, Large; case pack of 10
GLKL2040CP - Surface Mount Raised Floor Grommet, Extra Large; case pack of 10

Temperature Strip
Upsite Technologies Temperature Strip

Great Lakes now offers Upsite Technologies temperature strips; with a self-adhesive backing, the temperature strip can easily attach to most surfaces within your enclosure. Displaying both Fahrenheit (in increments of 2°) and Celsius(in increments of °1) readings, the temperature strip is accurate to within +/- 1°C. Actual temperature is denoted when liquid crystals in the temperature strip display green. When brown and blue appear on the strip, the actual temperature is between these two numbers. Temperatures will fall into one of three ranges as indicated by the colors at the bottom of the strip.

upsite® Technologies Temperature Strip

GL-Tempstrip - Single Upsite Technology Temperature Strip